      Currently, the light distribution of LED street lights is typically classified into types such as Type IM, Type IIM, Type IIIM, and Type VS. However, some street light tender projects still specify requirements using beam angle. Why is this the case? The answer lies in the use of two different classification systems: the first is the IES Luminaire Classification System (LCS), and the second is the NEMA classification (which is also included in the IESNA Handbook). Both systems describe the spatial distribution of light emitted by a luminaire, but each has its own characteristics. This article focuses on the IES Luminaire Classification System and its application in street light photometric classification, including different street light distribution types and beam angles.

 

What is the IES Luminaire Classification System (LCS)?

      The luminaire classification system proposed by the IES is a cornerstone of roadway lighting design. It defines luminaire types based on the lateral and longitudinal distribution of light on the road surface.

      Lateral distribution (also called transverse light distribution) is determined according to the relationship between the mounting height of the luminaire and the road width. Lateral distribution is identified by analyzing the candela trajectory of half-maximum intensity.

      Type I is suitable for narrow sidewalks, with light mainly distributed within 1 mounting height (MH) on both sides of the luminaire (i.e., the half-maximum intensity candela trajectory falls between 1 MH on the house side and 1 MH on the street side of the luminaire position).

      Types II and III are suitable for medium-width roads, where the half-maximum intensity points fall between 1.75 and 2.75 MH in front of the luminaire.

      Type IV is suitable for large-area lighting and has strong lateral throw capability, with the half-maximum intensity curve extending beyond 2.75 MH.

      The system also introduces longitudinal distribution. By analyzing the maximum intensity curve, luminaires are classified into short, medium, and long distributions:

      When the maximum intensity point falls within 1.0 MH to 2.25 MH on either side of the luminaire position, it is classified as a short distribution.

 

      For medium-distribution luminaires, the maximum intensity point lies between 2.25 MH and 3.75 MH.

      For long-distribution luminaires, the maximum intensity point lies between 3.75 MH and 6.0 MH.

      These three distribution types are respectively suitable for short, medium, and long pole spacings. Distributions are typically designed for a series of typical conditions, including mounting height, lateral position (overhang length), longitudinal spacing, the road width that needs effective illumination, and the arrangement of the luminaires.

 

Limitations of the LCS Classification and Practical Selection Advice

      LCS classification is based on the half-maximum and maximum candela curves. Because distributions that fall within the same range are defined as the same type, lighting performance within the same LCS classification inevitably varies-and in some cases the differences can be significant. In roadway lighting simulations, we have also used Type II lateral distributions to observe whether they can adequately illuminate different lanes; the results clearly show that the first distribution significantly outperforms the second. The same applies to longitudinal distributions of the same xxM class.

      Therefore, we recommend that if your project has specific information such as pole height (what factors determine street light height?), pole spacing, overhang length, setback distance, and tilt angle, you should select an appropriate distribution and perform lighting simulation according to your actual requirements, rather than choosing a distribution solely based on the relationship between pole height and road width or pole spacing. Otherwise, the result may fail to meet the project requirements.

 

      Although the LCS system provides a more scientific and systematic classification method, many technical specifications in actual street light tender projects still directly use "beam angle" as a mandatory requirement (for example, requiring a lateral beam angle ≥ 120° or a longitudinal beam angle of a certain value). This is because the concept of beam angle is more intuitive and easier to understand and verify on site. Beam angle is usually defined as the angle corresponding to the point where intensity drops to 50% of the maximum intensity. It is similar to the half-maximum intensity trajectory concept used in LCS, but far less comprehensive and precise than the LCS classification.

 

      Therefore, understanding the IES Luminaire Classification System helps us select and evaluate light distributions more accurately. When facing projects that still use beam angle requirements, it is also necessary to combine the complete photometric curve (IES file) with actual road parameters for lighting simulation verification. Ultimately, regardless of which classification system is adopted, the core goal of street light distribution remains the same: to achieve uniform, comfortable, efficient, and glare-free road surface illumination.